Get a Quote
Buchi 20/40/60 rule for Rotary Evaporators

Buchi 20/40/60 rule for Rotary Evaporators

1. Set water bath temperature to 60oC – It does not need to be higher! 2. The cooling water temperature should be below 20oC. 3. Adjust the needed vacuum for a solvent boiling point of 40oC according to list below. Reference: Buchi: List of Solvents

More details
Rotovap for sale -

Rotovap for sale -

5L Rotary Evaporator RotoVap Stainless Lab Equipment Digital Heating Bath Lift. $1,075.48. Was: $1,169.00. $79.00 shipping. or Best Offer. Only 1 left!

More details
How The Rotovap Is Useful -

How The Rotovap Is Useful -

A rotary evaporator (rotovap or rotatvap) refers to a kind of equipment for solvent evaporation under reduced pressure, which is composed of a vacuum system, a heated water or oil bath, a condenser and a motor that rotates the evaporation flask.

More details
What Are Rotovaps and How Can They be Used?

What Are Rotovaps and How Can They be Used?

A rotovap acts like a filter to separate the unwanted components in the extract as a final step to crude oil. The rotovap is a simple concept with a lot of moving parts. The material needs to be heated to the point of evaporation and then cooled and condensed. The process is like distillation but even more precise.

More details
How to use a Rotary Evaporator

How to use a Rotary Evaporator

Apr 01, 2010 If you are not lucky enough to have these and cannot release the joint you probably want to ask your teaching assistant for advice. If a mechanical pump is used instead of an aspirator to produce a vacuum, a secondary trap has to be used to prevent that the solvent destroys the membrane or is absorbed in the oil.

More details
How to use a Rotary Evaporator

How to use a Rotary Evaporator

Apr 01, 2010 Most labs use a simple water aspirator vacuum on their rotavaps, so a rotavap cannot be used for air and water-sensitive materials unless special precautions are taken i.e. additional traps are used. In the lab, the house vacuum line, a circulation bath or a membrane pump are used as source for the vacuum (40-50 torr).

More details
experimental chemistry - How to prevent losing solvent into the vacuum pump in rotovap ...

experimental chemistry - How to prevent losing solvent into the vacuum pump in rotovap ...

Apr 07, 2015 I think the answer is that if the vacuum is weak enough to vaporize the solvent under the hot water bath, but not under the cooler ambient air temperature, then the loss to the pump should be minimal. Indeed, this is what the instructions for the rotovap suggest. Question: In practice, what are the risks to losing solvent into the pump?

More details
Failures and Troubleshooting of a Rotary Evaporator

Failures and Troubleshooting of a Rotary Evaporator

Aug 08, 2019 The possible reasons can be concluded as follows. The internal gear may wear, or the driving section lacks of oil, or the motor fails, or the sealing ring wears. If it’s one of the first three reasons, stop using immediately and contact the manufacturer. If it’s the last reason, just replace the sealing ring. 4. There is an abnormal lifting.

More details
Buchi R114 Rotovap - Hamilton Instrument

Buchi R114 Rotovap - Hamilton Instrument

Buchi Rotavapor Model R-114. Complete with vertical water coil condenser. Dry ice/acetone condenser available at extra cost. 1 liter condensing and evaporating flask with all Necessary seals. Model B-480 4 liter oil or water heating Bath with a temperature range of 20 to 100C. Raise and lower system manually using quick lift.

More details
Buchi R200 Rotovap - Hamilton Instrument

Buchi R200 Rotovap - Hamilton Instrument

Buchi Rotavapor Model R-200. Complete with vertical water coil condenser. Dry ice/acetone condenser available at extra cost. 1 liter condensing and evaporating flask with all Necessary seals. Model B-490 4 liter oil or water heating Bath with a temperature range of 20 to 180C. Raise and Lower Bath with Electronic Switch.

More details
Rotary Vacuum Evaporator Continuous Cooling 100 Liter

Rotary Vacuum Evaporator Continuous Cooling 100 Liter

Eliminates dry ice, recirculating chiller, water and antifreeze. Footprint: 1.8 square feet. Water Evaporation. Yes. Ecodyst’s hydrogen is a high performance, smart self-cooling and small footprint rotary evaporator that’s eco-friendly, energy-efficient, and sustainable. It sets a new benchmark for rotovaps without using glycol, dry ice or ...

More details
RE-2000ABE small mini rotovap rotary evaporator

RE-2000ABE small mini rotovap rotary evaporator

Feature: RE-2000ABE rotary evaporators are the small rotovap independently developed by our company, including three models: RE-2000A rotary evaporator, RE-2000B rotary evaporator, and RE-2000E rotary evaporator.Use two-line large-capacity blue backlit LCD as the interface, and the control part uses high-performance single-chip microcomputer as the main control chip.The …

More details
Best Practices for Rotary Evaporator Maintenance

Best Practices for Rotary Evaporator Maintenance

Feb 21, 2020 It can also cause rust, resulting in irreparable damage, especially if the bath has an exposed heating element. If you’re using oil in your bath, you can get away with changing it less frequently, but it should still be cleaned out regularly. If the oil has been overheated at any point, it should not be reused. 3. Check Glassware Regularly for Damage

More details
Water/oil Dual-use Bath RE-501 5L Rotary Evaporator - Zhengzhou Zylab Instruments Co. Ltd

Water/oil Dual-use Bath RE-501 5L Rotary Evaporator - Zhengzhou Zylab Instruments Co. Ltd

Home / Rotary Evaporators / 5L Rotovap Water/oil Dual-use Bath, RE-501 5L Rotary Evaporator RE-501 5L Rotary Evaporator is an indispensable instrument for evaporation, concentration, crystallization, separation and solvent recovery in the research and production of medicine, chemical and biological products.

More details
How to clean up the silicone oil (e.g. dimethyl siloxane) of beakers after oil-bath ...

How to clean up the silicone oil (e.g. dimethyl siloxane) of beakers after oil-bath ...

How to clean up the silicone oil (e.g. dimethyl siloxane) of beakers after oil-bath heating? I have tried ultrasound treatment with a lot of detergent, heating at …

More details
Precautions for Using a Water Bath in the Rotovap

Precautions for Using a Water Bath in the Rotovap

Jan 16, 2019 Place the water bath in the center place where the evaporation flask is lifted vertically. Lower the host of the rotary evaporator slowly. Lower the evaporation flask until it is nicely placed inside the water bath. Add water into the water bath according to the capacity of the evaporation flask. Don’t add too much water.

More details
Rotovap Distillation: What Is A Rotary Evaporator?

Rotovap Distillation: What Is A Rotary Evaporator?

Jul 21, 2017 Connect vacuum pump to cold trap and cold trap to rotovap vacuum port. Turn on heat bath and set to 40C (113F). Once heat bath and coil have reached the desired temperature, turn on rotovap motor and set speed to approximately 100 RPM. Start vacuum pump and allow it to pull down for a few minutes before beginning injection.

More details
Falling Film vs. Rotovaps: the fracTron solution

Falling Film vs. Rotovaps: the fracTron solution

Mar 10, 2020 Figure 1.) A. Condenser, B. Heating Bath, C. Rotating Round Bottom Flask, D. Receiving Reservoir, E. Vacuum Pump. A mixture of winterized oil and ethanol is typically introduced to the round bottom flask which is then heated by the heating bath to vaporize volatile components from CBD oil.

More details
Bath Liquids for High-Temperature Applications Blog

Bath Liquids for High-Temperature Applications Blog

Mar 14, 2016 UPDATE (6/29/2016): We've ran into a few customers using vegetable oils in their rotary evaporator baths who were having issues with bath heating. Using a vegetable oil is not advisable as it has a much higher specific heat and viscosity than silicone oil or other synthetic oils made specifically for heating baths.

More details
Rotovap - General Discussions on StillDragon Community Forum

Rotovap - General Discussions on StillDragon Community Forum

Mar 20, 2015 ok, starting a thread for rotovap - rotary vacuum distillation... it makes some awesome distillate with little to no heat involved... you know you want this: Buchi 50 Liter Rotovap slightly used $154k original Price 2013 @ eBay. rotovap.jpg. 800 x 450 - 52K.

More details
How to use a rotovap

How to use a rotovap

Mar 26, 2019 How to use a rotovap. Firstly, ensure the receiving flask is empty. To empty the flask, carefully remove the clip and pour any solvent into the appropriate waste bottle. Carefully attached the receiving flask and secure with the clip. Ensure the air bleed is open. Turn on the rotary evaporator.

More details
Rotary Evaporation in the Kitchen - Cooking Issues

Rotary Evaporation in the Kitchen - Cooking Issues

May 19, 2009 Two key components of the rotovap allow for a gentle, precise, and efficient distillation not found in conventional distilling apparatuses: 1) the solvent is removed under vacuum, which lowers its boiling point, eliminating the need for high-temperature distillation, and 2) the rotation of the evaporating flask, immersed in a heated water bath ...

More details
Rotary Evaporation in the Kitchen - Cooking Issues

Rotary Evaporation in the Kitchen - Cooking Issues

Operation: Flying the Rotovap Here’s the information you’ve been waiting for: a long, nitty-gritty section on flying the rotovap. Correct Order to Set Up a Rotovap Plug water bath, rotovap, peristaltic pump, and vacuum pump into one 20 amp circuit. Plug chiller into separate 15-20 amp circuit. Do not attempt to run entire system off of one ...

More details
Rotovap - Lab Instrument Manufacturer

Rotovap - Lab Instrument Manufacturer

Rotary evaporators, commonly known as rotovaps , rotavaps or rotavapors, are extremely valuable to a number of downstream applications requiring efficient distillation solvent removal. Often combined with a vacuum pump, rotary evaporators are used to remove solvents from samples through evaporation. During this process, rotary evaporators reduce the pressure …

More details
Oil Baths in Laboratories Environmental Health and Safety

Oil Baths in Laboratories Environmental Health and Safety

Store the oil bath away from heat sources, including hot plates. When not in use, keep the oil bath covered with a metal cover or cover the bath container with aluminum foil, and store at room temperature. Before storing, label the bath with the contents of the oil (fluid name) as well as with the safe working temperature range of the fluid.

More details
What Are Rotovaps and How Can They be Used?

What Are Rotovaps and How Can They be Used?

The benefit to using a rotovap over a simple distillation system is that the rotation of the evaporating flask, combined with a heated water bath, increases the surface area of the product. This makes the distillation go faster and keeps the mixture evenly mixed and heated, to promote a stable and even evaporation.

More details
RotoVap vs Falling Film Evaporation - TruSteel LLC

RotoVap vs Falling Film Evaporation - TruSteel LLC

The RotoVap Limitations. For years, the industry standard for solvent recovery has been the rotary evaporator, or otherwise known as the RotoVap. A generic 20L RotoVap has a recovery rate of about 1.5 gallons per hour. For small-scale setups, this may suffice, but large-scale manufacturers have been forced to run multiple RotoVaps.

More details
Rotavapor R-300

Rotavapor R-300

The Smart distillations of the Rotavapor R-300 enable an automated, unattended process with optimized system parameters to take place. Users can flexibly program their own SOPs into the system and then monitor their distillations remotely via an app. System uptimes are substantially maximized with the BUCHI Cloud Services for smart self-service tools, and free updates by …

More details
Rotary Evaporator Only Information

Rotary Evaporator Only Information

The water bath temperature should not exceed the boiling point of the solvent! • The condenser could be overloaded since the evaporation rate will exceed the condensation capacity. Cannabis extracts require lower water bath temperatures (≈40 degrees Celsius). Oil baths can hold a higher temperature range than water baths.

More details
Rotavapor R-220 Pro

Rotavapor R-220 Pro

When BUCHI customers say the Rotavapor R-220 Pro is made to last, they mean it. The R-220 Pro is made of corrosion-free stainless-steel to enhance its durability and prolong its lifetime. The risk of product contamination is non-existent due to the use of highly chemical resistant materials and the robust industrial design ensures seamless 24 ...

More details
Related Post

Send Message to Us

48-hour idling test machine before leaving the factory. You can take the materials to the factory test machine. We will customize the solution according to your needs.

Get in Touch

Need more additional information or queries? We are here to help. Please fill in the form below to get in touch.

<script type="text/javascript" src="https://v1.cnzz.com/z_stat.php?id=1281085200&web_id=1281085200"></script>