Get a Quote
13 C Chemical Shift Table - Department of Chemistry

13 C Chemical Shift Table - Department of Chemistry

13C NMR Chemical Shift Table 140.0 120.0 130 110 215 200 180.0 165.0 60 10 80.0 60.0 70 40 95 80 60 30 70 40 80.0 55.0 125.0 115.0 220 200 180 160 140 120 100 80 60 40 20 0 ppm Alcohols Ethers Substituted Benzenes Alkenes Carbonyl: Ester Amide Carboxylic Acid Carbonyl: Aldehyde Ketone Alkanes Alkynes Amines

More details
Reagents Solvents - University of Rochester

Reagents Solvents - University of Rochester

2022 Alison Frontier, University of Rochester. Supported by a grant from the National Science Foundation. NSF Funding {+} This material is based upon work supported by the National Science Foundation under Grant Number CHE-1565813. Any opinions, findings, and conclusions or recommendations expressed in this material are those of the author(s) and do not necessarily …

More details
How to use a Rotary Evaporator

How to use a Rotary Evaporator

Apr 01, 2010 The solvent is removed under vacuum, is trapped by a condenser and is collected for easy reuse or disposal. Most labs use a simple water aspirator vacuum on their rotavaps, so a rotavap cannot be used for air and water-sensitive materials unless special precautions are taken i.e. additional traps are used. In the lab, the house vacuum line, a ...

More details
SOLVENT CHART - Producers Chemical

SOLVENT CHART - Producers Chemical

CHEMICAL CO. SOLVENT CHART 1355 South River Street • Batavia, Illinois 60510 TEL: 630.879.2700 • FAX: 630.879.2734 email: [email protected] www ...

More details
CHEMICAL RESISTANCE CHART - U.S. Plastic

CHEMICAL RESISTANCE CHART - U.S. Plastic

CHEMICAL RESISTANCE CHART RATINGS — CHEMICAL EFFECT A — No effect—Excellent B — Minor effect—Good 2. Polypropylene — Satisfactory to 72 F. C — Moderate effect—Fair D — Severe effect—Not recommended FOOTNOTES 1. P.V.C. — Satisfactory to 72 F. 3. Polypropylene — Satisfactory to 120 F. 4. Buna-N — Satisfactory for ...

More details
Chemical Resistance Chart Plastics International

Chemical Resistance Chart Plastics International

Chemical Resistance Chart; Legend. A = No Attack, possibly slight absorption. Negligible effect on mechanical properties. B = Slight attack by absorption. Some swelling and a small reduction in mechanical likely. C = Moderate attack of appreciable absorption. Material will have limited life.

More details
Eastman Solvents Formulation Tools

Eastman Solvents Formulation Tools

Eastman solvents comparison and reformulation tools Solvent Comparison Tool. The Solvent Comparison Tool provides pertinent technical information for Eastman and non-Eastman solvents such as physical and engineering properties, compares solvent and resin attributes, and obtain a resin solubility chart for various resins.

More details
GALVANIC REACTION CHART - Screws

GALVANIC REACTION CHART - Screws

GALVANIC REACTION CHART Below is a galvanic reaction chart for dissimilar metals. Please understand that green represents lower risk not no risk. It should be noted that if sacrificial plating is incorporated in the fastener design, then galvanic action can result in the deterioration of the sacrificial coating, rather than of the fastener.

More details
How Rotovap Solvent Chart -

How Rotovap Solvent Chart -

How Rotovap Solvent Chart ; The Rotary Evaporator. 2. Next, cold water is circulated through the rotovap condenser to condense the volatile solvent on the condenser coils and to prevent, as much as possible, the volatile solvent from vaporizing into the aspirator. Ice and a small amount of water are placed in the water-circulating pump.

More details
ILMVAC Vacuum Pump and Systems Catalog 2011-2012

ILMVAC Vacuum Pump and Systems Catalog 2011-2012

How to use this catalog and Pump Selection Reference Chart 1 Dry Vacuum Pumps (Oil-Free) Chemical Duty Diaphragm Pumps (MPC) 2-5 Standard Duty Diaphragm Pumps (MP) 6-8 Advanced Diaphragm Technology 9 Laboratory Vacuum Systems (LVS) 10-13 Standard Duty WOB-L and GEMINI Pumps 14-15 Scrollvac Scroll Pumps 16 Turbomolecular Pumping …

More details
Interface I-300 / I-300 Pro Technical data sheet

Interface I-300 / I-300 Pro Technical data sheet

Interface I-300 / I-300 Pro Technical data sheet The Interface I-300 or I-300 Pro are the central control unit for all process parameters of a Rotavapor R-300 system: rotation speed, temperature (heating bath and coolant), pressure, process time etc. Operating modes: manual, timer, continuous, AutoDest, drying.

More details
Common Issues With Rotary Evaporator Systems - USA Lab

Common Issues With Rotary Evaporator Systems - USA Lab

Its Motor Won’t Rotate. Another common issue with rotary evaporator systems is a faulty motor. To facilitate a quicker evaporation process of the solvent, a rotary evaporator will rapidly rotate and increase the solvent’s surface area. If the system’s indicator light is on but the motor isn’t rotating, there are several potential causes ...

More details
How to Speed Up Your Rotary Evaporation Process Blog

How to Speed Up Your Rotary Evaporation Process Blog

Jun 26, 2019 Using a rotovap is a crucial step in many processes as it enables you to gently and efficiently remove solvents from samples. In some cases, the rate of evaporation isn’t an issue, such as when you have very little solvent to evaporate or if time simply doesn't matter.

More details
Buchi 20/40/60 rule for Rotary Evaporators

Buchi 20/40/60 rule for Rotary Evaporators

Optimal Distillation parameters for a rotary evaporator vary according to solvent in use: 1. Set water bath temperature to 60oC – It does not need to be higher! 2. The cooling water temperature should be below 20oC. 3. Adjust the needed vacuum for a solvent boiling point of 40oC according to list below. Reference: Buchi: List of Solvents

More details
Organic Solvents NIOSH CDC

Organic Solvents NIOSH CDC

Organic solvents are carbon-based substances capable of dissolving or dispersing one or more other substances. Organic solvents can be carcinogens, reproductive hazards, and neurotoxins. Carcinogenic organic solvents include benzene, carbon tetrachloride, and trichloroethylene. Organic solvents recognized as reproductive hazards include 2 ...

More details
rotary evaporator pressure for ethanol

rotary evaporator pressure for ethanol

rotary evaporator pressure for ethanol and gas. Rotary evaporator laboratory for ethanol alcohol The rotary evaporator laboratory is operated under negative pressure conditions.the rotating bottle is rotated in the water bath to form a large-area film in the bottle, thereby effectively evaporating.The vapor formed by the solvent is condensed and collected in a receiving …

More details
Large Scale Rotary Evaporator-Rotovap-Industrial Vacuum Rotavap - UD ... - UD Technologies

Large Scale Rotary Evaporator-Rotovap-Industrial Vacuum Rotavap - UD ... - UD Technologies

Rotary Evaporator-Rotovap- Vacuum Rotavap. UD technologies are manufacturer,Supplier and exporter of Industrial and Large Scale Rotary Vacuum Evaporator from Vadodara,India and Suppliers to Indore,Hyderabad,Chennai,Mumbai and Ahmedabad. Rotary Film Evaporator is also known as rotavapor or rotovap or rotavap. Principle of Rotary Film evaporator. The Thin film …

More details
BUCHI Laboratory Equipment Product Overview

BUCHI Laboratory Equipment Product Overview

Rotavapor R-250 Best performance and highest ... logging, chart recording in real time and required interruption at anytime and anywhere. LyovaporTM L-300 ... organic solvents safely Dehumidifier B-296 Condition the drying air or work continuously with water and organic solvent mixtures under stable conditions

More details
Rotavapor R-220 SE Technical data sheet

Rotavapor R-220 SE Technical data sheet

Rotavapor R-220 SE Technical data sheet The Rotavapor R-220 SE is designed to fulfill a wide range of distillation applications in the in- dustrial environment. Safety, robustness and easy handling are the key benefits of this system. Seven different glass configurations and a wide range of accessories guarantees the perfect

More details
Industrial Rotary Evaporator Rotavap manufacturer

Industrial Rotary Evaporator Rotavap manufacturer

Sep 02, 2018 Industrial Rotary Vacuum Evaporator is essential equipment in Concentration of Heat Sensitive products by Gentle Evaporation.Rotary Evaporator is generally known also as Rotavapor-Rotovap-Rotavap. Heat sensitive material decomposes at higher temperature and prolonged exposure to Heat transfer surface .Rotary Evaporation saves against both reasons.

More details
Rotary Evaporator RE500/540 - Yamato Scientific

Rotary Evaporator RE500/540 - Yamato Scientific

Solvent Recovery Unit: This aspirator prevents discharge of dichloromethane, chloromethane, etc. This device extracts the organic solvent substances from gas generated by a rotary evaporator during concen tration work, and prevents the discharge of dangerous matter.

More details
Solvent Removal - Organic Chemistry at CU Boulder

Solvent Removal - Organic Chemistry at CU Boulder

Solvent Removal. It is often necessary to remove solvent from a solution to recover either a solid or a high-boiling liquid. There are several ways to do this. Distillation. Simple distillation can be used to remove solvent. Distillation works well if the solution is composed of a solid and a low-boiling solvent, or if the solution is composed ...

More details
Eastman Solvents Resources

Eastman Solvents Resources

Solvent Selector Chart (SOL-030) Select Language: Filter By: Brochures. ADD-COAT-021. Eastman products for coating and ink formulations. AGC-13421. Solvents for the agricultural market. CE-EU-COAT-8114. Formulating Decopaint-compliant 2K industrial wood-coating formulations. EMN-3845 ...

More details
Rotary Evaporator Only Information

Rotary Evaporator Only Information

Solvent tables for a certain temperature and a water bath at a set temperature can give the applied pressure for different solvents. • A solvent table, below, from a large rotary evaporator manufacturer, Buchi.

More details
Chemical Compatibility Database from Cole-Parmer

Chemical Compatibility Database from Cole-Parmer

The information in this chart has been supplied to Cole-Parmer by other reputable sources and is to be used ONLY as a guide in selecting equipment for appropriate chemical compatibility. Before permanent installation, test the equipment with the chemicals and under the specific conditions of your application. Ratings of chemical behavior listed ...

More details
Buy Rotavapor For Sale New Used Prices

Buy Rotavapor For Sale New Used Prices

The R-3 is an entry level rotary evaporator. It fulfills all the basic needs of the customer, specifically targeting the educational market. The quality of the instrument’s mechanical and glass components have not been sacrificed to compensate for the new lower cost.

More details
Rotavapor R-300

Rotavapor R-300

The Smart distillations of the Rotavapor R-300 enable an automated, unattended process with optimized system parameters to take place. Users can flexibly program their own SOPs into the system and then monitor their distillations remotely via an app. System uptimes are substantially maximized with the BUCHI Cloud Services for smart self-service tools, and free updates by …

More details
The Rotary Evaporator

The Rotary Evaporator

The warm vapors of the solvent now encounter a cold condenser coil and recondense, dripping off the coiled glass tube into the reservoir. As long as there is solvent in the pot, condensed solvent will collect in the reservoir. This ceases when the last bit of solvent evaporates from the pot. 5. The speed control rotates the pot in the warm water

More details
Chemical Compatibility Chart ISM - Industrial Spec

Chemical Compatibility Chart ISM - Industrial Spec

This Chemical Compatibility Chart is a shorthand tool for describing the suitability of miniature fluidic and pneumatic component materials for use in contact with various chemicals. Use this chart to help guide your component selection. Use our Chemical Compatibility Chart as guide for evaluating the resistance of polymer and metal materials to a wide range of chemicals …

More details
Heidolph Instruments : Solvent data

Heidolph Instruments : Solvent data

Water. H 2 O. 100.0. 72. Xylene (isomeric mixture) C 8 H 10. 137–143. 25. Download solvent data as PDF.

More details
Rotavapor R-220 Pro

Rotavapor R-220 Pro

When BUCHI customers say the Rotavapor R-220 Pro is made to last, they mean it. The R-220 Pro is made of corrosion-free stainless-steel to enhance its durability and prolong its lifetime. The risk of product contamination is non-existent due to the use of highly chemical resistant materials and the robust industrial design ensures seamless 24 ...

More details
Related Post

Send Message to Us

48-hour idling test machine before leaving the factory. You can take the materials to the factory test machine. We will customize the solution according to your needs.

Get in Touch

Need more additional information or queries? We are here to help. Please fill in the form below to get in touch.