Get a Quote
Operation of (hot plate cintex cic 10) - ICH APPS

Operation of (hot plate cintex cic 10) - ICH APPS

2.6 Monitor cautiously while operating the heating for the chances of bumping of theliquids. 2.7 Switch of the hot plate after usage and after coming to room temperature. 2.8 Always use hot plate only inside the fume hood. 2.7 Don’t place any flammable liquids or solids directly in beakers on heating mantle.

More details
Procedures - University of California Davis

Procedures - University of California Davis

5. Handling Procedures. Equipment. Each still consists of a heating mantle, heating mantle controller, 2 litre round bottom flask (24/40 female joint), still …

More details
SOP for Laboratory Safety : Pharmaceutical Guidelines

SOP for Laboratory Safety : Pharmaceutical Guidelines

5.0 PROCEDURE 5.1 Solvent Extraction 5.1.1 Release the pressure developed on shaking in the Separating funnel by Inverting the funnel with the stopper securely held and opening the tap with care. Point the funnel away from the eyes and the naked flames, or heating mantle.

More details
Heating Mantles - Facilities Management

Heating Mantles - Facilities Management

A heating mantle can easily generate enough heat to vaporize most organic materials and will melt a flask if used on full power. Always plug the heating mantle into a grounded variable voltage transformer or percentage timer control (which runs at full power but cycles on and off to control the heat). Such devices are often known by the trademarked name, Variac (below, left) …

More details
SOP on Good Laboratory Practices (GLP) - Pharmaceutical Guidance

SOP on Good Laboratory Practices (GLP) - Pharmaceutical Guidance

Apr 09, 2016 SOP on Good Laboratory Practices (GLP) Objective:To lay down a procedure for operation of “Hot Plate”. Scope: This Standard Operating Procedure is applicable to Quality Control Department followed at pharmaceutical company name with location. Responsibility:QC personnel shall be responsible to follow the procedure as per SOP. …

More details
Naira price for Electrothermal Heating Mantle Archives

Naira price for Electrothermal Heating Mantle Archives

Electromantle EM0500CE Heating Mantle ... STANDARD OPERATING PROCEDURES FOR SACHET WATER FACTORIES. Basic Equipment and Materials for Bottle or Sachet Water Production in Nigeria. BASIC STEPS TO GET NAFDAC NUMBER FOR YOUR FACTORY PRODUCED BOTTLE/SACHET WATER IN NIGERIA.

More details
GLASSCO Heating Mantle

GLASSCO Heating Mantle

General Remarks:- The operator has to make sure that the Heating mantle is stable. Put only Glass flask on the heating mantle that fit the heating mantle's volume. Always replace the fuse from the same type current. Always put a Glass flask in the heating mantle. Never put beaker anything else without flask. Never rotate the Heat knob out of their ranges to avoid …

More details
Heat Gun SOP SafetyDocs PDF Word Templates

Heat Gun SOP SafetyDocs PDF Word Templates

Heat Gun Safe Operating Procedure. This Heat Gun Safe Operating Procedure (SOP) provides a way for your business to outline step-by-step safe processes when using a heat gun. Heat Gun SOP: Provides instructions on the use of the equipment both prior to and during operation. Ensures workers recognise and manage associated hazards and risks involved.

More details
1. Procedure/Hazardous Material: 2. Department: 3.

1. Procedure/Hazardous Material: 2. Department: 3.

Heating Bath SOP 2013 1 Standard Operating Procedure Heat Sources and Heating Baths 1. Procedure/Hazardous Material: Includes, but not limited to ovens, hot plates, heating mantles and tapes, oil baths, salt baths, sand baths, hot-air guns, and microwave ovens. 2. Department: Campus wide 3. Revision Date: February 2013 4. Special Notifications:

More details
Heating Mantle - PCE Instruments

Heating Mantle - PCE Instruments

Heating Mantle. In case of heating mantle it goes about a device which is used in laboratories to heat special media in glass vessels. Due to the various sizes of the glass vessels the exact amounts of liquids can be heated. The scope of volumes of heating mantle at PCE ranges from 100 ml up to 10

More details
Heating Mantle at Thomas Scientific

Heating Mantle at Thomas Scientific

Heating Mantles. United Scientific Supplies. These heating mantles are designed for use with round bottom flasks. Features include polyurethane coated aluminum exteriors and a high quality knitted mantle with glass fiber underlay for uniform distribution of heat. Maximum operating temperature is 400C. Mantles can be used in a wide range….

More details
SOP: Flammable Liquids PennEHRS

SOP: Flammable Liquids PennEHRS

Jan 24, 2022 Reviewed 1/2022 (KB) This SOP primarly describes the hazards, restrictions, and controls for Flammable Liquids. Information about flammable solids can be found in SOP: Reactive Chemicals and flammable gases are described in …

More details
Standard Operating Procedure - NSF

Standard Operating Procedure - NSF

May 03, 2017 Standard Operating Procedure Updated: May 3, 2017 Page 3 of 18 a. There are two (2) sources of heating the MSF: 1. Latent waste heat from the UPS and Researcher instrumentation that includes computers, chillers, laser heads, heat exchangers, fans, compressors, etc. as part of their data collection suite. Other than encouraging Researcher and

More details
Module 3: Heating Under Reflux (Fischer Esterification)

Module 3: Heating Under Reflux (Fischer Esterification)

Procedure. Part I: Heating Under Reflux (See Figure 1) In a 50 mL round bottom flask (rbf), dissolve 150 mg of 4-amino-3-nitrobenzoic acid in 10 mL of methanol. Add a magnetic stirring rod and 1-2 boiling chips. Connect the heating mantle to the monkey bars or support stand and sit the rbf into the heating mantle

More details
Mini Pressure Reactor Standard Operating Procedure

Mini Pressure Reactor Standard Operating Procedure

Slide the heating mantle onto the reactor vessel and tighten the screw clamp. Flip the heater switch on the front of the control tower to begin heating. The reaction temperature may need to be set a few degrees higher to achieve the desired temperature. ... Mini Pressure Reactor Standard Operating Procedure ...

More details
SPECIFICATIONS ASAP 2420 - Micromeritics

SPECIFICATIONS ASAP 2420 - Micromeritics

SPECIFICATIONS ASAP 2420 ELECTRICAL Voltage 100/115/230 VAC ( 10%) Frequency 50 or 60 Hz Power 800 VA, exclusive of vacuum pumps, which are powered separately ENVIRONMENT Temperature 10 to 30 C operating -10 to 55 C storage or shipping Humidity Up to 90% (non-condensing) for instrument CAPACITY

More details
BET Standard Operation Procedure (SOP)

BET Standard Operation Procedure (SOP)

Standard Operating Procedure (SOP) Surface Area Pore Size Distribution Analyses Name: BET - Autosorb-1C ... Put the cell into a heating mantle (pinch mantle to open the mouth) using a

More details
Standard Operating Procedure - USGS

Standard Operating Procedure - USGS

Standard Operating Procedure . for the USGS Reston, Virginia Environmental Organic Geochemistry Laboratory . ... -6-position Electrothermal Electromantle ME heating mantle (250-mL round bottom flasks) -Recirculating cooler for condensers: Neslab Model RTE-110 .

More details
Standard Operating Procedure - Yale University

Standard Operating Procedure - Yale University

Standard Operating Procedure FLAMMABLE LIQUIDS This standard operating procedure (SOP) is intended to provide general guidance on how to safely work with flammable liquids. ... heating mantles or hot air baths. • If flammable liquids must be heated in an oven, make sure the oven is appropriately designed for ...

More details
Standard Operating Procedures

Standard Operating Procedures

Standard Operating Procedure _____ Read the EHS Standard Operating Procedures Fact Sheet before filling out this form. ... (shock hazards), the temperature and temperature control of the heating mantle and contents (burn and fire hazards), chemical toxicity and reactivity of the solvents and sodium reducing agent, cleanup and disposal of still ...

More details
Standard Operating Procedures - Columbia University

Standard Operating Procedures - Columbia University

Standard Operating Procedures 1. Standard Operating Procedures OVER VIEW In the following laboratory exercises you will be introduced to some of the glassware and tech - niques used by chemists to isolate components from natural or synthetic mixtures and to purify ... (you may need to slightly heat for complete dissolution, but make sure the ...

More details
STANDARD OPERATING PROCEDURES - WTAMU

STANDARD OPERATING PROCEDURES - WTAMU

STANDARD OPERATING PROCEDURES SOP No. 24.01.01.W1.22AR Chemical Safety Procedure Approved: August 15, 2010 ... oil bath, heating mantle, hot air bath, etc. Use ground straps when transferring flammable chemicals between metal containers to avoid generating static sparks. Use a fume hood when there is a possibility of dangerous vapors ...

More details
OPERATING AND SAFETY INSTRUCTIONS

OPERATING AND SAFETY INSTRUCTIONS

the heating zone (area inside mantle where heating element is located). This is 450 degrees C. Some mantles have more than one heating zone. The power input to each zone should be controlled with a suitable control device. If liquid level drops in the vessel, the upper heating zone should be operated at reduced power or turned off.

More details
Related Post

Send Message to Us

48-hour idling test machine before leaving the factory. You can take the materials to the factory test machine. We will customize the solution according to your needs.

Get in Touch

Need more additional information or queries? We are here to help. Please fill in the form below to get in touch.

<script type="text/javascript" src="https://v1.cnzz.com/z_stat.php?id=1281085200&web_id=1281085200"></script>